Geothermal Exploration in Taranaki and Waikato: Unlocking New Energy Opportunities in New Zealand New Zealand is expanding its geothermal ambitions beyond the country’s established development zones. Two Māori-led exploration projects in Taranaki and South Waikato have received a combined NZ$5.95 million in government grants to investigate previously underexplored geothermal resources and assess their potential to support regional growth, energy resilience, employment, and decarbonisation. The initiatives reflect a broader shift in geothermal development. While New Zealand’s geothermal industry has traditionally focused on high-temperature resources suitable for electricity generation, the new projects will also examine lower-temperature heat that could serve industrial, agricultural, commercial, and community applications. Government Funding for Two Exploration Projects The New Zealand Government has allocated NZ$3 million from the Regional Infrastructure Fund to the Taranaki Ge...
Novi Sad Advances Miseluk Geothermal Heating Plant as Serbia Embraces Low-Carbon District Energy
Novi Sad is moving ahead with an ambitious district-heating project that could change how new urban neighborhoods in Serbia are supplied with thermal energy. The city’s public heating utility, JKP Novosadska toplana, has launched a new tender for the design and construction of the Miseluk heating plant, a hybrid facility that will combine geothermal energy, natural gas and solar technology.
The procurement is valued at approximately 892.5 million Serbian dinars excluding value-added tax, equivalent to roughly €7.6 million. The project is designed to reach a final heating capacity of up to 30 megawatts and will serve the growing Miseluk area of Novi Sad.
The tender represents a renewed attempt to deliver the project after an earlier procurement procedure was cancelled in September 2026 because all submitted bids were considered unacceptable. Companies participating in the new procedure must submit their offers by December 3, 2026.
A Strategic Project for Miseluk
Miseluk is one of Novi Sad’s emerging urban development areas. Located on the city’s right bank of the Danube, the neighborhood is expected to accommodate residential, commercial, public and sports facilities as construction progresses.
The area already forms part of Novi Sad’s broader district-heating planning, but it does not yet have a dedicated local heat source. This creates both an infrastructure challenge and an opportunity. Instead of extending the city’s existing heating system over long distances, the municipality is planning a local facility capable of using renewable heat close to where it will be consumed.
The project is therefore more than the construction of another boiler plant. It is intended to establish an integrated energy system for a developing urban district, with the capacity to expand alongside the growth of the local heat demand.
The final plant is expected to support heating for buildings in the Mišeluk 3 and Mišeluk 4 areas. Its phased design will allow Novosadska toplana to match investment and generation capacity with the pace of construction and connection of new users.
What the New Tender Includes
The procurement covers the design and construction of the Miseluk heating plant. It also includes the installation and connection of equipment required to supply early users before the permanent facility reaches full operation.
The planned system will be built in stages. The first phase includes:
- A water-to-water geothermal heat pump with a minimum heating capacity of 415 kilowatts.
- Use of groundwater at approximately 16 degrees Celsius.
- A groundwater flow rate of about seven litres per second.
- Integration with a natural-gas boiler plant rated at 1 megawatt.
- A thermal storage tank with a capacity of 100 cubic metres.
- An additional gas-fired boiler plant with a capacity of 4 megawatts.
- A second thermal storage tank with a capacity of 200 cubic metres.
- Hybrid photovoltaic-thermal panels capable of producing both electricity and useful heat.
- Construction of the plant building and supporting infrastructure.
The building and associated infrastructure will be sized with later expansion in mind. This is important because the first phase is not intended to represent the final operating configuration. Instead, it will create the physical and technical foundation for a larger low-temperature district-heating system.
How the Hybrid System Will Work
The proposed plant will use several energy sources rather than relying on a single technology. Geothermal energy is expected to provide the renewable base-load component, while gas-fired boilers will provide additional capacity during periods of high demand or when renewable output is insufficient.
The geothermal component will use a water-to-water heat pump. Groundwater at approximately 16 degrees Celsius is not hot enough to supply conventional district heating directly, but a heat pump can raise its temperature to a level suitable for building heating.
The heat pump transfers thermal energy from the groundwater into the district-heating circuit. Electricity is required to operate the equipment, but the system can deliver more heat than the electrical energy it consumes because it extracts additional energy from the underground water source.
The performance of a heat pump is commonly described by its coefficient of performance, or COP. A system with a COP of 4, for example, can deliver approximately four units of heat for every unit of electricity used, although actual performance depends on water temperature, delivery temperature, equipment design and operating conditions.
The use of thermal storage will help the plant operate more efficiently. Storage tanks can absorb heat when generation exceeds immediate demand and release it when demand rises. This can reduce the need for frequent boiler start-ups and help coordinate geothermal, solar and gas-based production.
The Role of Natural Gas
Natural gas will remain part of the Miseluk system, particularly during the early stages of development. The inclusion of gas boilers may appear inconsistent with the project’s renewable-energy objectives, but it reflects the practical requirements of reliable district heating.
Geothermal resources may not provide sufficient capacity to cover peak winter demand. A heat pump also operates most efficiently when the required supply temperature and demand conditions are within its design range. Gas boilers can therefore provide supplementary and backup capacity.
The planned approach allows the system to begin operating before the geothermal resource and renewable components can meet the entire heat load. As the district develops, additional heat pumps, solar equipment and other renewable technologies could increase the share of low-carbon energy.
The long-term objective is not necessarily to eliminate gas immediately, but to limit its role to peak-load, reserve and backup operation. In a well-designed system, the gas boilers would operate fewer hours than a conventional stand-alone heating plant.
Solar Technology at the Plant
Another distinctive feature of the project is the planned installation of hybrid photovoltaic-thermal, or PVT, panels.
Conventional photovoltaic panels convert sunlight into electricity. PVT panels combine photovoltaic generation with thermal collection, allowing them to produce electricity and capture heat from the panel surface. The recovered heat can potentially be used in the district-heating system or for other low-temperature applications.
This technology may be particularly useful in a hybrid heating plant because it can contribute to both sides of the energy balance. Electricity from the panels can support heat-pump operation, while recovered thermal energy can reduce the need for gas-fired generation.
The effectiveness of PVT systems depends on factors such as solar radiation, panel orientation, operating temperatures and the ability of the heating network to use heat when it is available. Thermal storage can improve the value of solar energy by allowing heat collected during sunny periods to be used later.
The inclusion of PVT technology indicates that the Miseluk facility is being designed as an integrated energy hub rather than a traditional boiler house.
Phased Expansion Toward 30 Megawatts
The Miseluk plant is planned as a modular facility. The first stage will establish the initial geothermal, gas and solar systems, but later phases will expand generation capacity as the neighborhood grows.
The second phase is expected to include another water-to-water heat pump. It will also provide for an additional gas-fired boiler plant with a capacity of 4, 6 or 8 megawatts, depending on the development of the local heating load.
In the final phase, additional boiler capacity will be installed so that the overall heat source can reach up to 30 megawatts. This capacity will not necessarily be required from the beginning. Installing all equipment immediately could create unnecessary capital costs and leave the plant underused during the early years of the district’s development.
A phased approach offers several advantages:
- Investment can be aligned with actual customer connections.
- Equipment can be added as new buildings are completed.
- The system can incorporate technological improvements over time.
- Early operational experience can inform later design decisions.
- The city can reduce the risk of constructing excessive capacity too soon.
This type of modular planning is particularly valuable for newly developing neighborhoods, where construction schedules and occupancy levels can change.
The Temporary Boiler Solution
Before the permanent plant is completed, some future users will require a reliable source of heat. To address this need, the project includes a temporary containerized boiler plant with an approximate capacity of 1 megawatt.
The temporary unit is intended to serve customers expected to connect during 2027 and 2028. It will supply an initial part of the heating load while the main facility is being designed and constructed.
A separate tender for the temporary boiler plant is already underway. Its installation and connection are included within the broader scope of the heating-plant construction works.
Temporary boiler plants are commonly used when new developments need early service but permanent infrastructure is still under construction. They can reduce delays for building occupants, although they may have higher operating costs and lower efficiency than the completed system.
For Miseluk, the temporary solution is also a way to support the gradual commissioning of the district-heating network. Once the permanent plant becomes operational, the temporary equipment can potentially be removed, retained as emergency capacity or reassigned elsewhere, depending on the final system design.
Fourth-Generation District Heating
Novosadska toplana has identified the Miseluk project as part of its strategy for developing a fourth-generation district-heating system through 2030.
Fourth-generation district heating generally emphasizes lower distribution temperatures, greater use of renewable sources, improved system efficiency and stronger integration with buildings and other energy networks.
Traditional district-heating systems often operate at relatively high temperatures to deliver heat over long distances. Lower-temperature systems reduce distribution losses and make it easier to integrate sources such as geothermal energy, solar thermal systems, industrial waste heat and large heat pumps.
However, low-temperature heating requires coordination with connected buildings. Radiators, underfloor systems, heat exchangers and domestic hot-water systems must be designed or adjusted to operate effectively at the available temperatures.
New neighborhoods such as Miseluk offer an advantage because energy performance can be considered during the planning and construction of buildings. Developers can incorporate improved insulation, larger heat-exchanger surfaces and lower-temperature internal heating systems from the outset.
Why Geothermal Energy Matters
Geothermal energy has several characteristics that make it attractive for district heating. Unlike solar and wind energy, geothermal heat can be available day and night and does not depend directly on daily weather conditions.
For heating applications, geothermal resources do not need to reach the very high temperatures required for electricity generation. Moderate-temperature groundwater can still be valuable when combined with a heat pump.
Direct-use geothermal heating can also be more efficient than using geothermal resources to generate electricity and then converting that electricity back into heat. The most suitable application depends on the resource temperature, flow rate, geology and local demand.
Serbia has been examining ways to expand the use of geothermal resources for heating and other direct applications. The country’s geothermal potential has been estimated at approximately 800 megawatts, while its national energy and climate planning includes an increase in the share of renewable energy by 2030.
The Miseluk project could demonstrate how geothermal energy can be linked directly to urban development instead of being treated as an isolated resource project.
Exploration and Resource Uncertainty
The success of a geothermal heating system depends on the quality and long-term performance of the underground resource. A well may provide water at the expected temperature but still fail to deliver the required flow rate or sustainable production volume.
Exploration work is therefore important. Hydrogeological investigations and exploratory wells help determine the temperature, chemistry, pressure and flow characteristics of the resource. They also help assess whether production and reinjection can be managed without damaging the aquifer.
The Miseluk concept is connected with ongoing efforts to better understand the geothermal conditions in the area. Research has included exploratory work intended to evaluate the resource for future heating use.
The final operating model may require careful management of groundwater. Depending on the hydrogeological conditions, the system could need reinjection to return water underground after heat extraction. This can help maintain pressure and reduce environmental impacts, although reinjection design presents its own technical challenges.
Benefits for Novi Sad
The heating plant could provide several benefits for Novi Sad and the Miseluk district.
First, it would create a local heat source for a rapidly developing area. Local generation can reduce dependence on long transmission routes and improve supply resilience.
Second, the system could lower emissions compared with a heating plant based entirely on fossil fuels. The precise reduction will depend on the operating hours of the heat pumps, the carbon intensity of electricity, the contribution of solar energy and the use of gas boilers during peak periods.
Third, the project could reduce exposure to fuel-price volatility over time. Geothermal energy has significant upfront development costs, but the underground heat resource itself does not need to be purchased in the same way as natural gas.
Fourth, the project may help Novi Sad build technical experience in managing low-temperature district heating, heat pumps, thermal storage and hybrid renewable systems.
Finally, the plant could raise the attractiveness of Miseluk as a location for new housing, public infrastructure and commercial development. Reliable heating infrastructure is a fundamental requirement for any expanding urban district.
Challenges Facing the Project
Despite its potential, the project faces several risks.
The first is procurement risk. The previous tender was cancelled after all bids were deemed unacceptable, showing that the project may face difficulties related to pricing, technical requirements, bidder qualifications or the completeness of submitted offers.
The second is construction and coordination risk. The plant must be integrated with the district-heating network, groundwater infrastructure, electrical systems, gas connections, storage tanks and future building connections.
The third is geothermal-resource risk. Actual groundwater temperatures and flow rates may differ from initial assumptions. Long-term sustainability must also be demonstrated through monitoring and responsible operation.
The fourth is financial risk. The estimated procurement value covers a major infrastructure investment, but the final cost could change because of inflation, equipment prices, construction conditions, financing terms and design modifications.
The fifth is demand risk. If residential and commercial development occurs more slowly than expected, the plant could operate below its planned capacity for an extended period. Conversely, faster development could require additional capacity earlier than expected.
These risks do not undermine the project, but they emphasize the need for detailed design, transparent procurement, strong supervision and realistic demand forecasting.
Implications for Investors and Contractors
The tender may attract companies specializing in district heating, heat pumps, geothermal engineering, boiler systems, solar technology, civil construction and energy management.
Because the project combines several technologies, bidders will need to demonstrate more than conventional boiler-plant experience. They may need to coordinate hydrogeology, heat-pump design, thermal storage, gas systems, PVT panels, electrical infrastructure and network integration.
For investors and developers, the project could provide an early indication of the commercial potential of low-temperature district heating in the Western Balkans. If the system performs well, similar concepts could be applied in other Serbian cities with suitable geothermal resources and expanding urban districts.
The project also has a potential demonstration value beyond Serbia. Fourth-generation district heating is receiving increasing attention across Europe as cities seek to decarbonize heat, which is often more difficult than decarbonizing electricity.
A Model for Future Urban Energy
Miseluk’s planned heating plant reflects a broader change in the way cities think about energy infrastructure. Instead of building separate systems for gas, electricity, heating and water, planners are increasingly looking for ways to connect multiple energy sources and technologies.
The proposed facility will use geothermal heat as a renewable base resource, gas for flexibility and backup, solar technology for additional energy production, heat pumps for temperature upgrading and storage tanks for balancing supply and demand.
This combination is not completely fossil-free, but it is more flexible than a single-source system. It also allows the renewable share to increase over time as the district expands and new technologies become economically attractive.
The project’s success will depend on execution. The tender must produce a capable contractor, the geothermal resource must perform as expected, the network must be well managed and customers must connect at a pace that supports the investment.
If those conditions are met, Miseluk could become an important example of how a growing neighborhood can be planned around renewable district heating from the beginning. Novi Sad would gain a new local heat source, while Serbia would gain practical experience in combining geothermal energy, solar systems, heat pumps and conventional backup generation.
Next Steps
The immediate priority is the completion of the new procurement procedure. Interested companies must submit their bids by December 3, after which the offers will be evaluated and a contract can be awarded if the process proceeds successfully.
Following the award, the project will move through design finalization, permitting, construction, equipment installation and network connection. The temporary boiler plant will be important during the transition period, particularly for users expected to connect in 2027 and 2028.
The longer-term objective is to establish a 30-megawatt heating source capable of supporting Miseluk’s development while reducing dependence on conventional fossil-fuel generation.
The project’s significance extends beyond its headline value or final capacity. It represents an attempt to integrate renewable heat into urban planning, use infrastructure in phases and create a flexible district-heating system suited to a changing energy market. If delivered as planned, the Miseluk heating plant could become a practical reference point for Serbia’s geothermal ambitions and for the future of low-carbon heating in the region.
Source: Ekapija

Comments